Search results for "Corneal Stroma"
showing 10 items of 17 documents
Structural, ultrastructural, and morphometric study of the zebrafish ocular surface: a model for human corneal diseases?
2018
Purpose: A morphological and morphometric study of the adult zebrafish ocular surface was performed to provide a comprehensive description of its parts and to evaluate its similarity to the human. Materials and Methods: The eyes of adult zebrafish were processed for light, transmission and scanning electron microscopy, and for immunohistochemical stain of corneal nerves; a morphometric analysis was also performed on several morphological parameters. Results: The corneal epithelium was formed by five layers of cells. No Bowman’s layer could be demonstrated. The stroma consisted of lamellae of different thickness with few keratocytes. The Descemet’s membrane was absent as the flat and polygon…
Impact of Corneoscleral Contact Lens Usage on Corneal Biomechanical Parameters in Keratoconic Eyes
2019
Objective To analyze the changes in corneal biomechanical parameters of keratoconic eyes with and without intracorneal ring segment (ICRS) implants after 1 year of corneoscleral contact lens (CScL) wear. Methods Seventy-four eyes of 74 patients were divided into three groups: healthy subjects (29 eyes, control group), and 2 groups of subjects with keratoconic eyes (one group of 20 eyes with ICRS implants and one of 25 eyes without them), which were fitted with CScL. Corneal hysteresis (CH), corneal resistance factor (CRF), and corneal-compensated intraocular pressure (IOPcc) were evaluated before fitting CScL and after 1 year of CScL wear. In addition, endothelial cell count (ECC) and centr…
Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis.
2012
To evaluate the efficacy, predictability, and safety of implantation of Ferrara-type intrastromal corneal ring segments (ICRS) for refractive correction of paracentral keratoconus.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Snellen uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation for keratoconus. The tunnels for ICRS implantation were created with a femtosecond laser. The power vector and the Alpins method were used to analyze postoperative refractive outcomes.The study evaluated 56 eyes of 49 patients. The mean UDVA was 0.17 ± 0.14 (SD) preoperatively and 0.41 …
Excimer laser photorefractive keratectomy for high myopia
1995
Abstract One hundred and thirty-three eyes of 103 patients had photorefractive keratectomy with a slit scan mode excimer laser for myopia ranging from −6.00 to −22.00 diopters (D). The epithelium was removed with 20% ethanol, and the ablation was done with a tapered profile surrounding the optical zone. Patients were divided into two groups based on preoperative myopia: Group A, −6.00 D to −12.00 D (88 eyes); Group B, −12.50 D to −22.00 D (45 eyes). In Group A, mean preoperative refraction was −9.59 ± 1.79 D. Mean postoperative refraction was −0.29 ± 1.47 D at one month, −0.85 ± 1.68 D at three months, −1.17 ± 2.04 D at six months, and −0.56 ± 0.74 D at one year. Anterior stromal haze was g…
Long-term comparison of corneal aberration changes after laser in situ keratomileusis: mechanical microkeratome versus femtosecond laser flap creatio…
2010
Purpose To compute and compare visual acuity, refractive outcomes, and anterior corneal aberration changes after myopic laser in situ keratomileusis (LASIK) with flap creation by a mechanical microkeratome and by a femtosecond laser. Setting Private practice refractive surgery center, Valencia, Spain. Design Comparative case series. Methods Patients were assigned to have LASIK flap creation with a mechanical microkeratome (Carriazo-Barraquer) or a femtosecond laser (IntraLase). The Visx S2 excimer laser was used for myopic ablation in all cases. Main outcome measures included uncorrected and corrected distance visual acuities and the defocus equivalent. Higher-order aberrations (HOAs) were …
Single versus double femtosecond laser pass for incomplete laser in situ keratomileusis flap in contralateral eyes: Visual and optical outcomes
2011
Purpose To evaluate visual acuity, refractive outcomes, and anterior corneal higher-order aberrations (HOAs) after myopic laser in situ keratomileusis (LASIK) with uneventful single femtosecond laser pass versus double pass performed for intraoperative suction loss. Setting Private refractive surgery center, Valencia, Spain. Design Cohort study. Methods After the LASIK flap was created with a single pass of an Intralase femtosecond laser in 1 eye and a double pass in the fellow eye, the ablation was performed with a Visx S2 laser. At 12 months, the refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and anterior corneal HOAs were measured with 4.0 mm and 6.0 mm pup…
Lattice Corneal Dystrophy Type 1
2014
PURPOSE To evaluate the question whether lattice corneal dystrophy type 1 (LCD1) is of epithelial or stromal origin. METHODS The landmark of advanced LCD1 shows central superficial haze and paracentral stromal lattice lines. In 16 eyes of 8 affected individuals of 2 families, a penetrating keratoplasty was performed. The follow-up was 8 to 16 years after penetrating keratoplasty. Slit-lamp documentation of the patients was evaluated in direct and indirect illumination with dilated pupil to assess the horizontal and vertical pattern of new deposits on the corneal graft. Three affected patients of 2 families are demonstrated in detail. A DNA analysis was performed. RESULTS Gene identification…
Early clinical outcomes after small incision lenticule extraction surgery (SMILE)
2018
Abstract Purpose Dry eye is known to impact on clinical outcomes after laser vision correction and the use of a newer ‘all femtosecond laser’ surgical approach may be associated with less impact on the ocular surface post-operatively. The purpose of this study was to evaluate the early clinical outcomes and tear instability after the first small incision lenticule extraction (SMILE) cases undertaken by three surgeons at a single site in the UK. Methods Retrospective audit. Seventy-one eyes of 37 patients underwent SMILE surgery using the Zeiss VisuMax laser system (Carl Zeiss Meditec, Germany). Uncorrected and corrected distance visual acuity, spherical equivalent refraction, fluorescein en…
Femtosecond laser–assisted intrastromal corneal ring segment implantation for high astigmatism correction after penetrating keratoplasty
2013
PURPOSE: To assess the visual and refractive outcomes of femtosecond laser-assisted implanta- tion of Ferrara-type intrastromal corneal ring segments (ICRS) in post-penetrating keratoplasty (PKP) eyes. SETTING: Instituto OftalmolFernOviedo, Spain. DESIGN: Cohort study. METHODS: Patients with previous PKP had ICRS implantation after femtosecond laser tunnel creation. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation. The power vector method was used to analyze refractive errors preoperatively and postoperatively. RESULTS: This study enrolled 32 eyes of 30 patients. The mean UDVA (Snell…
Multilayer amniotic membrane transplantation in severe ocular graft versus host disease
2001
To clarify the usefulness of multilayer amniotic membrane transplantation in an unusual case of calcareous corneal degeneration in a patient with graft-versus-host disease.A 20-year-old Caucasian woman had bilateral calcareous corneal degeneration of one year of evolution, secondary to graft-versus-host disease. Treatment for both eyes with topical steroids and antibiotic ointment was not successful. Right eye had a spontaneous corneal perforation, and a three-layer circle amniotic membrane graft was applied to the whole cornea.During a follow-up period of 20 months we observed stability of the corneal epithelium and stroma. The amniotic membrane-covered area showed rapid epithelization, re…